{
  "page": "https://firstlinksafetyservices.com/osha-trends/2026-08",
  "window_start": "2025-09-01",
  "window_end": "2026-08-31",
  "data_as_of": "2026-10-29",
  "source": "First Link Safety OSHA citation trends, from U.S. Department of Labor OSHA enforcement data (federal OSHA only)",
  "license": {
    "name": "CC BY 4.0",
    "url": "https://creativecommons.org/licenses/by/4.0/"
  },
  "unit": "Federal OSHA violation items (one per cited item), by issuance date",
  "tables": [
    {
      "scope": "all",
      "total_citations": 38827,
      "rows": [
        {
          "rank": 1,
          "standard": "1926.501",
          "citation": "29 CFR 1926.501",
          "title": "Fall protection: duty to have",
          "citations": 4618,
          "share_pct": 11.9,
          "share_change_pts": -1.6,
          "median_current_penalty_usd": 3972,
          "pct_penalties_reduced": 40.6
        },
        {
          "rank": 2,
          "standard": "1910.1200",
          "citation": "29 CFR 1910.1200",
          "title": "Hazard communication",
          "citations": 2250,
          "share_pct": 5.8,
          "share_change_pts": 0,
          "median_current_penalty_usd": 2483,
          "pct_penalties_reduced": 69
        },
        {
          "rank": 3,
          "standard": "1910.147",
          "citation": "29 CFR 1910.147",
          "title": "Lockout/tagout (control of hazardous energy)",
          "citations": 2101,
          "share_pct": 5.4,
          "share_change_pts": 0.4,
          "median_current_penalty_usd": 6384,
          "pct_penalties_reduced": 69.9
        },
        {
          "rank": 4,
          "standard": "1926.1053",
          "citation": "29 CFR 1926.1053",
          "title": "Ladders",
          "citations": 1919,
          "share_pct": 4.9,
          "share_change_pts": -0.5,
          "median_current_penalty_usd": 2838,
          "pct_penalties_reduced": 41.1
        },
        {
          "rank": 5,
          "standard": "1926.451",
          "citation": "29 CFR 1926.451",
          "title": "Scaffolds: general requirements",
          "citations": 1901,
          "share_pct": 4.9,
          "share_change_pts": 0.7,
          "median_current_penalty_usd": 3227,
          "pct_penalties_reduced": 46.6
        },
        {
          "rank": 6,
          "standard": "1910.134",
          "citation": "29 CFR 1910.134",
          "title": "Respiratory protection",
          "citations": 1791,
          "share_pct": 4.6,
          "share_change_pts": 0.1,
          "median_current_penalty_usd": 2780,
          "pct_penalties_reduced": 72.3
        },
        {
          "rank": 7,
          "standard": "1910.178",
          "citation": "29 CFR 1910.178",
          "title": "Powered industrial trucks (forklifts)",
          "citations": 1586,
          "share_pct": 4.1,
          "share_change_pts": -0.1,
          "median_current_penalty_usd": 3547,
          "pct_penalties_reduced": 70.6
        },
        {
          "rank": 8,
          "standard": "1926.503",
          "citation": "29 CFR 1926.503",
          "title": "Fall protection training",
          "citations": 1432,
          "share_pct": 3.7,
          "share_change_pts": -0.7,
          "median_current_penalty_usd": 2838,
          "pct_penalties_reduced": 41.6
        },
        {
          "rank": 9,
          "standard": "1926.102",
          "citation": "29 CFR 1926.102",
          "title": "Eye and face protection",
          "citations": 1275,
          "share_pct": 3.3,
          "share_change_pts": -0.5,
          "median_current_penalty_usd": 2270,
          "pct_penalties_reduced": 34.6
        },
        {
          "rank": 10,
          "standard": "1910.212",
          "citation": "29 CFR 1910.212",
          "title": "Machine guarding",
          "citations": 1225,
          "share_pct": 3.2,
          "share_change_pts": 0.2,
          "median_current_penalty_usd": 5906,
          "pct_penalties_reduced": 79.5
        }
      ]
    },
    {
      "scope": "construction",
      "total_citations": 19278,
      "rows": [
        {
          "rank": 1,
          "standard": "1926.501",
          "citation": "29 CFR 1926.501",
          "title": "Fall protection: duty to have",
          "citations": 4536,
          "share_pct": 23.5,
          "share_change_pts": -2.2,
          "median_current_penalty_usd": 3972,
          "pct_penalties_reduced": 40.3
        },
        {
          "rank": 2,
          "standard": "1926.1053",
          "citation": "29 CFR 1926.1053",
          "title": "Ladders",
          "citations": 1884,
          "share_pct": 9.8,
          "share_change_pts": -0.7,
          "median_current_penalty_usd": 2838,
          "pct_penalties_reduced": 40.8
        },
        {
          "rank": 3,
          "standard": "1926.451",
          "citation": "29 CFR 1926.451",
          "title": "Scaffolds: general requirements",
          "citations": 1839,
          "share_pct": 9.5,
          "share_change_pts": 1.7,
          "median_current_penalty_usd": 3227,
          "pct_penalties_reduced": 45.5
        },
        {
          "rank": 4,
          "standard": "1926.503",
          "citation": "29 CFR 1926.503",
          "title": "Fall protection training",
          "citations": 1397,
          "share_pct": 7.2,
          "share_change_pts": -1.2,
          "median_current_penalty_usd": 2838,
          "pct_penalties_reduced": 40.8
        },
        {
          "rank": 5,
          "standard": "1926.102",
          "citation": "29 CFR 1926.102",
          "title": "Eye and face protection",
          "citations": 1259,
          "share_pct": 6.5,
          "share_change_pts": -0.7,
          "median_current_penalty_usd": 2270,
          "pct_penalties_reduced": 34.2
        },
        {
          "rank": 6,
          "standard": "1926.20",
          "citation": "29 CFR 1926.20",
          "title": "General safety and health provisions",
          "citations": 668,
          "share_pct": 3.5,
          "share_change_pts": 0.1,
          "median_current_penalty_usd": 3900,
          "pct_penalties_reduced": 48.2
        },
        {
          "rank": 7,
          "standard": "1926.100",
          "citation": "29 CFR 1926.100",
          "title": "Head protection",
          "citations": 565,
          "share_pct": 2.9,
          "share_change_pts": -0.2,
          "median_current_penalty_usd": 2483,
          "pct_penalties_reduced": 42.6
        },
        {
          "rank": 8,
          "standard": "1926.502",
          "citation": "29 CFR 1926.502",
          "title": "Fall protection systems and practices",
          "citations": 501,
          "share_pct": 2.6,
          "share_change_pts": 0.1,
          "median_current_penalty_usd": 3972,
          "pct_penalties_reduced": 47.5
        },
        {
          "rank": 9,
          "standard": "1910.1200",
          "citation": "29 CFR 1910.1200",
          "title": "Hazard communication",
          "citations": 500,
          "share_pct": 2.6,
          "share_change_pts": 0.1,
          "median_current_penalty_usd": 2270,
          "pct_penalties_reduced": 50.8
        },
        {
          "rank": 10,
          "standard": "1926.1153",
          "citation": "29 CFR 1926.1153",
          "title": "Respirable crystalline silica",
          "citations": 500,
          "share_pct": 2.6,
          "share_change_pts": 0.3,
          "median_current_penalty_usd": 2767.5,
          "pct_penalties_reduced": 65.2
        }
      ]
    },
    {
      "scope": "general_industry",
      "total_citations": 19549,
      "rows": [
        {
          "rank": 1,
          "standard": "1910.147",
          "citation": "29 CFR 1910.147",
          "title": "Lockout/tagout (control of hazardous energy)",
          "citations": 2069,
          "share_pct": 10.6,
          "share_change_pts": 0.3,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 2,
          "standard": "1910.1200",
          "citation": "29 CFR 1910.1200",
          "title": "Hazard communication",
          "citations": 1750,
          "share_pct": 9,
          "share_change_pts": -0.3,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 3,
          "standard": "1910.134",
          "citation": "29 CFR 1910.134",
          "title": "Respiratory protection",
          "citations": 1487,
          "share_pct": 7.6,
          "share_change_pts": -0.3,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 4,
          "standard": "1910.178",
          "citation": "29 CFR 1910.178",
          "title": "Powered industrial trucks (forklifts)",
          "citations": 1425,
          "share_pct": 7.3,
          "share_change_pts": -0.7,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 5,
          "standard": "1910.212",
          "citation": "29 CFR 1910.212",
          "title": "Machine guarding",
          "citations": 1214,
          "share_pct": 6.2,
          "share_change_pts": 0.3,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 6,
          "standard": "1910.303",
          "citation": "29 CFR 1910.303",
          "title": "Electrical systems: general requirements",
          "citations": 718,
          "share_pct": 3.7,
          "share_change_pts": -0.4,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 7,
          "standard": "1910.132",
          "citation": "29 CFR 1910.132",
          "title": "Personal protective equipment",
          "citations": 647,
          "share_pct": 3.3,
          "share_change_pts": 0.2,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 8,
          "standard": "1910.305",
          "citation": "29 CFR 1910.305",
          "title": "Electrical wiring methods and equipment",
          "citations": 511,
          "share_pct": 2.6,
          "share_change_pts": -0.5,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 9,
          "standard": "5(a)(1)",
          "citation": "OSH Act §5(a)(1)",
          "title": "General Duty Clause",
          "citations": 433,
          "share_pct": 2.2,
          "share_change_pts": 0,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        },
        {
          "rank": 10,
          "standard": "1910.37",
          "citation": "29 CFR 1910.37",
          "title": "Exit routes: maintenance and safeguards",
          "citations": 411,
          "share_pct": 2.1,
          "share_change_pts": 0,
          "median_current_penalty_usd": null,
          "pct_penalties_reduced": null
        }
      ]
    }
  ]
}
